VitalCNC - What's New ===================== The newest version is at the top. Each entry lists what is new, what was fixed and what works differently, and anything to check after you upgrade. ------------------------------------------------------------------------------- Version 1.2.2503 5 Nov 2026 ------------------------------------------------------------------------------- NEW * M98 subprograms in the same file A program can keep its M98 routines after the M30, as Mach4 programs do: "M98 P001 L3" runs the "O001" routine that follows the main program three times and comes back. O001, O0001 and O1 all mean P1, and the routine shares the program's # parameters. A separate file (o1.ngc beside the program) still works when the file has no such routine. Stop, Run From Line and resume work inside a routine. * Diagnostics > EtherCAT: Status and Parameters Both windows open from the Diagnostics menu and stay open while you work. CHANGES * Cycle Start after a Stop asks before it moves back along the line If the tool stopped part-way along a line, Cycle Start asks: go back and re-run the line, or carry on from where it stopped (offered on a straight move). Cancel is the default, so pressing Enter never moves the machine. If you Stop again in a line you carried on from, you can go back to the start of the whole line. * Cycle Start after a jog opens Return and Resume If the machine was moved after the Stop, Cycle Start opens the Return and Resume box, which goes back to where it stopped. Cancel is the default here too. * Enable is refused at once when two motors use the same output The message names the motors and the output. Before, the machine showed enabled until the controller turned it off. BUG FIXES * "#14 = FUP[...]" stopped the program A parameter can be set straight to a function, such as FUP, FIX, ABS or SIN, without brackets around it, as Mach4 programs write it. * Stop turned off the spindle and coolant when the setting said not to With "Stop turns off spindle and coolant" unticked (Config > General), a Stop near the end of a program could still turn them off. * Analog output of a spindle read 0 V on the I/O screen The spindle's analog channel now shows the volts it is commanded. ------------------------------------------------------------------------------- Version 1.2.2502 5 Nov 2026 ------------------------------------------------------------------------------- BUG FIXES * Thin grey lines beside screen objects With the Windows display scale at 125%, 150% or 175%, moving the mouse over an object could leave a thin grey line along its bottom and right. ------------------------------------------------------------------------------- Version 1.2.2501 4 Nov 2026 ------------------------------------------------------------------------------- BEFORE YOU UPGRADE * Install this version of VitalCNC before you put firmware 1.1.8 on a controller. * Use VSI Device Manager 7.02 from now on. It can program both Mach and VitalCNC firmwares on VSI HiCON motion controllers. Older versions, and the Mach4 plugin, say "No Response from Device" after loading a file. Use 7.02 instead. NEW * HiCON 7866 and 7854 are now compatible with VitalCNC firmware These two boards do not have VitalPLC or EtherCAT. * Toolpath view: arrowheads on the origin axes The axes can also keep a fixed size on the screen. See the Toolpath object's properties. * VitalPLC, a real ladder logic PLC, is now available. It runs inside the HiCON motion controller thereby providing microsecond response time. More on that soon with the installer release in the coming days. CHANGES * Drilling cycles go up to the R plane before the first XY move G98 also no longer retracts below R. Check any program that relied on the old moves by running it in the air first. * Rigid tapping: Stop takes Z back from the spindle at once BUG FIXES * Undo left a new object on the screen designer If you had just changed another object, the first Undo took back that change and the new object stayed. Undo now removes the new object first. Paste and Duplicate work the same way. * Ctrl+Z did nothing after dropping an object while typing in a property * Jog buttons kept jogging after release if they had no Up action. Now the software does auto shutoff on mouse up. ------------------------------------------------------------------------------- Version 1.2.2500 4 Nov 2026 ------------------------------------------------------------------------------- BEFORE YOU UPGRADE * Controller firmware comes as a separate file This setup carries no controller firmware. Vital Systems sends you the file for your controller. To put it on: Diagnostics > HiCON Driver Status > Controller Firmware... > Use another file... Firmware 1.1 starts fresh, as described for version 1.2.2496 below: register the controller again afterwards, and check its settings. Mach4 does not connect to a controller on this firmware. NEW * Coolant buttons work at any time FLOOD and MIST now work while a program runs, in Feed Hold and after a Stop, and each one leaves the other alone. * Spindle Stop during a pause In Feed Hold you can stop the spindle to look at the cut. Cycle Start turns it back on and waits for it to get up to speed before anything moves (3 seconds unless you change it). * Warning for a Junction Deviation outside the sensible range Config now warns when it is 0 or very small, which makes the machine slow down or stop at every join, or so large that it cuts corners. 0.01 mm is a good place to start if your machine stutters on curves. * Motion packets carry more moves Long programs with short moves run with more in hand. CHANGES * PID tuning buttons have moved The buttons that move the machine (Enable axis, Apply gains, Execute, Cancel) are now along the bottom left. The buttons for the graph are above it on the right, and RUN / STOP is now TRACE RUN / STOP. BUG FIXES * Return and Resume showed 0.000 mm The window now shows how far the machine really is from where the program stopped. * The message after jogging and pressing Cycle Start was cut off After a jog, Cycle Start refuses and tells you to press RETURN & RESUME. That instruction now comes first, so it is not lost at the screen edge. * Moved to a different controller: Inputs/Outputs kept the old one VitalCNC said it had moved your signals to the new board, but the page still showed the old one, and Save wrote it back, so the message came back at every connect. The page now shows the board connected, and Save puts an end to the message. * Firmware older than 7.46 could not be updated from VitalCNC It said no controller was connected. It updates now. * Unreadable tooltips in the EtherCAT status window ------------------------------------------------------------------------------- Version 1.2.2496 1 Nov 2026 ------------------------------------------------------------------------------- BEFORE YOU UPGRADE * After the controller firmware update, register the controller again This version comes with VitalCNC firmware 1.00 for the HiCON M31 / V31 and offers to put it on the controller (below). Firmware 1.00 starts fresh: the controller's registration and the features activated with VSI Device Manager are cleared. After the update, register the controller again as described for version 1.2.2494: Diagnostics > HiCON Driver Status > Controller Registration. Until then VitalCNC connects and shows the machine but does not enable it. With firmware 1.00 every feature is available and nothing needs activating. The Activation tab in VSI Device Manager shows no features for it; that is expected. NEW * Controller firmware update from VitalCNC (HiCON M31 / V31) VitalCNC now carries the firmware for the controller. When it connects to a controller with older firmware, it offers the update, once per session, and never while the machine is enabled. You can also open it any time: Diagnostics > HiCON Driver Status > Controller Firmware... Press Update firmware; the update takes well under a minute and the window shows each step. Do not switch the controller off or unplug its network cable until the window says it is done. If an update is interrupted anyway, the controller waits for firmware, and VitalCNC offers to finish the update the next time it connects. A controller whose firmware upgrade period has ended is not updated; the window says so. Contact Vital Systems. Other HiCON boards get their firmware in a later version. CHANGES * Registration messages say what is missing The status bar shows CONTROLLER MISSING REGISTRATION, CONTROLLER NOT SUPPORTED or CONTROLLER NOT VERIFIED, and pressing Enable on such a controller explains what to do, starting with the problem, for example "Controller missing registration: register it in Diagnostics > HiCON Driver Status > Controller Registration." ------------------------------------------------------------------------------- Version 1.2.2495 30 Oct 2026 ------------------------------------------------------------------------------- BEFORE YOU UPGRADE * If you run programs with cutter compensation (G41/G42), upgrade first Every earlier version has the fault fixed below. Until you upgrade, do not run a G41/G42 program on a part. * Controller registration (version 1.2.2494, below) still applies. BUG FIXES * Cutter compensation no longer cuts into the part at a retract or dwell With G41 or G42 on, a G00 Z retract, a G04 dwell or an M0/M1 pause first moved the tool sideways from the compensated path back onto the programmed contour, at the depth it was cutting, and only then retracted or paused. With an 8 mm cutter that is a 4 mm move into the wall. The tool now retracts straight up from where it is, and dwells or pauses where it is. A G40 on the exit move runs straight from the compensated position to the programmed end point, with no extra move first. The toolpath view shows the same path the machine runs. ------------------------------------------------------------------------------- Version 1.2.2494 30 Oct 2026 ------------------------------------------------------------------------------- BEFORE YOU UPGRADE * Your controller must be registered, or Enable is refused From this version on, VitalCNC enables only a controller registered by Vital Systems. With a controller that is not registered, or whose firmware cannot be registered yet, VitalCNC still connects and shows the machine, but Enable is refused and the status bar says CONTROLLER NOT REGISTERED - ENABLE REFUSED. There is no grace period: the cut-off date described for version 1.2.2492 no longer applies, and a request or certificate made with 1.2.2492 (HCREQ1 / HCCERT1) cannot be used. New controllers come registered from the factory. Every HiCON is supported except the HiCON OEM (7752) and the 7766. To register a controller you already own: 1. Install this version and connect to the controller. Disable the machine. 2. Open Diagnostics > HiCON Driver Status and press Controller Registration... The window shows whether the controller is registered and its "Controller identity". If it says the firmware cannot be registered, update the controller firmware first. 3. Press Create registration request. A line starting with HCREQ2 appears; it holds the controller's identity. Press Copy and email the line to Vital Systems (sales@vitalsystem.com). 4. Vital Systems replies with a line starting with HCCERT2. Paste it into the lower box and press Install certificate. The status changes to Registered, and Enable works. If the window asks you to switch the controller off and on, do that before step 3. A registration belongs to one controller: a replacement controller needs its own. Manual: section 9.6. NEW FEATURES * Tool length offset on/off from the screen (VCNC-MILL profile) TOOLS > TOOL LENGTH (G43) turns the tool length offset on for the tool in the spindle, and off again (G49); its lamp shows whether it is on. It works with the machine disabled, is greyed while a program runs, and refuses when the spindle is empty (use SET TOOL... first). On your own screen: the button action "ToolLength" and the lamp state "Tool Length Active (G43)". Manual: section 5.4. WORKS DIFFERENTLY * Reset, M2 and M30 keep the tool length offset on The tool is still in the spindle, so its length stays in force. Only G49 turns it off. 5-axis tool tip control (G43.4) still ends with the program and on Reset. If a screen button or macro relied on Reset to cancel G43, add a G49 to it. * G2/G3 arcs whose centre does not fit are refused An arc's centre (I, J, K) must be the same distance from its start and its end. If the two differ by more than 0.05 mm, that line is an error, and the message gives both distances: correct the centre or write the arc with R. Before, such an arc ran as a spiral that the preview did not show. Smaller differences, normal in CAM output, still run, and the preview now draws them exactly as the machine moves. Manual: section 0.3. * G90.1 arc centres follow the work offset With absolute arc centres (G90.1), I, J and K are now work coordinates: the active work offset, G92, scaling and rotation apply to them. They were measured from machine zero, so a G90.1 arc under a work offset cut in the wrong place. Check any program that uses G90.1. BUG FIXES * A program that loops forever (WHILE [1 EQ 1], an M99 back to the top) no longer makes the screen slow. The preview stops adding a path that only repeats itself, and stops altogether when the loop never ends; the status bar says which line the program loops back to. Anything after a loop that does end is still drawn. Manual: section 0.3. * 5-axis profiles (such as VCNC-MILL): with the tool length offset on, the path drawn while the program ran sat a little above the program's preview. They now line up. * The status bar's error tooltip was hard to read on dark screens. * The VCNC-MILL profile's inputs named the wrong board, so every M31 user saw a red I/O mismatch message on the first connect. The mismatch message now names both boards. * Config > Motors: the "EtherCAT VFD" output type is gone. It never moved a motor; a profile that has it loads as Disabled. ------------------------------------------------------------------------------- Version 1.2.2493 27 Oct 2026 ------------------------------------------------------------------------------- NEW FEATURES * Connector and pin numbers for every HiCON input and output The pin lists in Config > Inputs and Config > Outputs, and the HiCON status window, now show where each pin is on the board, so you no longer need the manual to wire one. For example, on a DSPMC input DI.00 shows "J1-10". - M31 / V31: J1 Input 1-8, J3 Input 9-16 and J10 Output 1-8, as printed on the board. The J12, J6, J5 and J7 pins were already labelled. - DSPMC, 7866, 7757, EC01, HiCON Mini, HiCON OEM and SwiftCut: the connector and pin. A relay output says "relay". A pin that needs the extended I/O key, or that the EC01 shares with its analog adapter, says so. On these boards, a pin with no label is one the board does not have. ------------------------------------------------------------------------------- Version 1.2.2492 27 Oct 2026 ------------------------------------------------------------------------------- NEW FEATURES * Controller registration VitalCNC now checks that the controller it is connected to is a genuine HiCON. New controllers come registered from the factory; a controller you already own is registered once, by you: Diagnostics > HiCON Driver Status > Controller Registration... creates a request line to email to Vital Systems, and installs the certificate that comes back. Until the cut-off date an unregistered controller works as before and the status bar shows CONTROLLER NOT REGISTERED as a reminder; after it, Enable is refused until the controller is registered. The registration survives firmware updates, power loss and controller crashes. Needs a controller firmware with registration support; the window says so if yours must be updated first. Manual: section 9.6. * Feed override from a knob A potentiometer on an analog input can set the feed override. Bind the input in Config > Inputs (for example Analog Input 1), then choose it in Config > General > Feed Override Knob and type the knob's reading at each end and the override you want there (for example 0 to 10 V gives 0 to 150 %). The "Now" line shows the live reading while you set it up. While the knob's input is bound, the knob sets the feed override; the slider, the screen buttons and the handwheel only show it. Manual: section 6.8. * Soft limits on/off from the screen (VCNC-MILL profile) The DIAG tab has a SOFT LIMITS button with an LED, so you can turn the soft limits off for a moment without opening Config. * Set Current Tool from the screen (VCNC-MILL profile) SET TOOL... on the TOOLS tab asks for the tool number and sets it, for machines without a tool changer. * Jog with several keys at once Holding two jog keys moves both axes; releasing one key stops only that axis. * Enable button and jog switches on the control panel Bind them in Config > Inputs: - "Enable Toggle": each press enables or disables the machine, like the Enable button on the screen. - "Jog X +" / "Jog X -" (and the other axes): the axis jogs while the input is on, at the screen's jog rate. A joystick is wired as one switch per direction. An input that is already on when VitalCNC starts or when the machine is enabled does nothing until it is released. Manual: section 6.9. * Config > Homing: "Also refuse MDI and jogging until homed" When ticked, MDI and jogging are refused until every axis is homed, not only program runs. * Type the spindle speed (VCNC-MILL profile) Click the commanded RPM (it has a blue border) and type a speed. The CW and CCW buttons now only start the spindle in that direction, at the speed you typed; they no longer run it at full speed. A spindle that is already turning changes to the new speed at once. On your own screens: a Label showing Spindle RPM with "Run Mode edit" set to Number does this. WORKS DIFFERENTLY * A thread or rigid tap that fails in the cut now stops the spindle and the axes, disables the machine and shows a Machine Fault window with the reason. Before, the program simply ended with a line of red text at the bottom of the screen. Enable again to carry on. A thread or tap refused before it starts (not activated, no encoder) still only stops the program. * Single Block, Optional Stop and Block Skip are greyed out while a program runs. A change made then did not apply where the program was. Change them before Cycle Start, or while the program is stopped at an M0, M1 or single-block stop. BUG FIXES * Config pages accepted a decimal comma on PCs set to a European regional format and then read the number back wrongly. Numbers are always typed with a decimal point now, whatever the Windows regional format. * Single Block stayed on "Preparing program" for ever when the program's first line moves nothing (for example "S300 M3"). It now stops after that line and Cycle Start steps on. * The VCNC-MILL profile mapped the C axis to motor 5, whose output is off. The C axis is no longer mapped; set it up on the Axes and Motors tabs if your machine has one. * Diagnostics > Registers with "Allow editing" ticked: typing on a register's name renamed it in the list. Only the value can be edited now; double-click anywhere on the row to change it. ------------------------------------------------------------------------------- Version 1.2.2488 24 Oct 2026 ------------------------------------------------------------------------------- BEFORE YOU UPGRADE (HiCON M31 owners) * VitalCNC no longer switches the M31's HwEN and DrEN outputs by itself. If your drives are enabled from these outputs, bind them in Config > Outputs: HwEN -> "Controller Online" DrEN -> "Enable" Until you do, the drives will not be enabled. Outputs 8 and 11 used to come on at every Enable even with nothing bound to them; now only the outputs you bind are ever switched. NEW FEATURES * Motion inhibit after Enable Some drives need a moment after they are enabled before they follow a move. Config > General > Machine Enable > "Motion inhibit after enable (s)" sets that wait (for example 2.5; leave it blank for none). While it counts down, the motion buttons are greyed out, an amber bar on the status bar shows the time left, and every move is refused: jog, MDI, Cycle Start, Run From Here, Return on Path, homing, Go To Work Zero and the MPG. Nothing starts by itself when the wait ends. * New output signals - "Controller Online": on while VitalCNC is connected to the controller, whether the machine is enabled or not. - "Motor 0 Enable" to "Motor 7 Enable": one enable output per motor. On a HiCON it switches with that motor (outputs 0-31). * Lua scripting - E-stop from a script: vc.estop("reason") stops the machine the same way a wired E-stop input does, and shows the reason. Use it to combine several stop sources, such as a pendant E-stop and a door switch. Enable is refused for as long as the script keeps asking. This does not replace your wired E-stop circuit. - Signal handlers in plc.lua: vc.on_rising, vc.on_falling and vc.on_change run your code when an input or signal changes, with an optional debounce time. No need to remember the last state yourself. - Machine buttons from a script: vc.cycle_start, vc.feed_hold, vc.stop, vc.home_all and vc.mdi("G0 Z0") do what the screen buttons do, with the same checks. If one is refused (for example Cycle Start while the machine is disabled), the status bar says why. - vc.controller_online() tells a script whether the controller is connected. Screen scripts also get Core.isControllerOnline() and Core.isMotionInhibitAfterEnable(). - The Lua debugger can try all of the above without a machine. * VCNC-MILL profile: plc.lua has a ready-made example, off until you turn it on: a three-button panel, Z to the top, a door lamp and a door E-stop. * Manual: chapter 2 is now "Lua Scripting", with new sections on pressing the machine's buttons from a script, screen scripts (main.lua), signal handlers, a table of signal handlers for a button panel, and adding a second E-stop source. BUG FIXES * Disabling the machine (Disable button, E-stop, or the controller dropping out) now turns the spindle and coolant off. Before, the spindle could keep running, and the same S M3 after enabling again did nothing. A plain Stop still leaves the spindle running, as before. * A Digital Spindle turned at 1/60 of the programmed speed. It now runs at the speed in the S word, and keeps turning after a Stop (like an analog spindle) so a Resume does not start cutting with the spindle stopped. * A program that loops for ever (for example WHILE [1 EQ 1]) showed the load bar stuck for about 11 seconds and then "Preview error". It now loads in a few seconds with its toolpath, and the status bar says the program loops and may not end. * Saving such a program in the editor started a new preview every time, so the editor seemed not to close. Loading another file, saving, or closing VitalCNC now stops any preview still running, straight away. * Reverse jog could be started while the machine was disabled. * Config crashed on opening an older profile that still had the old digital output settings. They are now carried over to the new bindings. * MotionScope could crash when a channel was added. ------------------------------------------------------------------------------- Version 1.2.2487 22 Oct 2026 ------------------------------------------------------------------------------- BUG FIXES * VitalCNC could crash at the splash screen on PCs with an older Microsoft Visual C++ runtime. Setup now installs the runtime when the PC's copy is too old.